TEMPERATURE CONTROL SYSTEM WITH AC-AC CONVERTER BASED ON FUZZY LOGIC CONTROL

Authors

  • Abdul Muis Prasetia Program Studi Teknik Elektro, Fakultas Teknik, Universitas Borneo Tarakan
  • Dedy Harto Program Studi Teknik Elektro, Fakultas Teknik, Universitas Borneo Tarakan

DOI:

https://doi.org/10.33752/reaktom.v2i2.204

Abstract

Abstrak
Makalah ini menyajikan sistem pengaturan suhu dengan konverter AC-AC melalui metode fuzzy logic control, penggunaan konverter AC-AC dilatarbelakangi oleh banyaknya aplikasi pengaturan suhu menggunakan pemanas listrik dan umumnya menggunakan prinsip on-off. Karena keterbatasan range pengaturan tegangan yang dapat diberikan, maka kontrol tegangan secara on-off kurang dapat memberikan akurasi nilai keluaran yang dibutuhkan sistem, sehingga untuk beberapa aplikasinya dapat menimbulkan tanggapan sistem pengaturan temperatur yang kurang baik. Untuk meningkatkan kinerja pengaturan suhu dengan memperluas range pengaturan tegangan digunakan konverter AC-AC. Pada penelitian ini usulkan pengaturan konverter dengan metode fuzzy logic kontrol. Hasil pengujian menunjukkan bahwa konverter dapat berfungsi dengan baik dan respon dapat mengikuti setpoint. Fuzzy logic control menunjukkan Rise time sebesar 3 menit, serta ketika telah mencapai setpoint yaitu 30ºC, suhu sedikit berosilasi dengan error steady state 0%.
Kata Kunci: Suhu, Fuzzy logic control, Konverter AC-AC
Abstract
This paper presents temperature control system with AC-AC converter based on fuzzy logic control method, the selection of AC-AC converters is motivated by the many applications of temperature control system using electric heaters and generally using on-off principle. Due to the limited range voltage settings, then the on-off voltage control is less able to provide the accuracy of required output value of the system, so for some applications it can lead to bad temperature control system response. To improve the temperature performance by extending the range of voltage settings used AC-AC converter. In this research, propose the converter arrangement with fuzzy logic control method. The results show converter can function well and the response can follow setpoint. Fuzzy logic control shows 3 minutes rise time, when it reaches 30ºC set point the temperature is slightly oscillated with 0% steady state error.
Keywords: Temperature, Fuzzy logic control, AC-AC converter.

Downloads

Download data is not yet available.

Downloads

Published

2017-10-27

How to Cite

Prasetia, A. M., & Harto, D. (2017). TEMPERATURE CONTROL SYSTEM WITH AC-AC CONVERTER BASED ON FUZZY LOGIC CONTROL. Reaktom : Rekayasa Keteknikan Dan Optimasi, 2(2). https://doi.org/10.33752/reaktom.v2i2.204

Issue

Section

Articles